Enterasys Networks CSX7000 User Manual Page 595

  • Download
  • Add to my manuals
  • Print
  • Page
    / 729
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 594
Central Site Remote Access Switch 595
S
YSTEM
C
OMMANDS
Call Control Commands
Calling <phone number> at <data rate>, device PPP
The phone number will show what is sent to the switch. Any imbedded dashes will have
been removed. The data rate that is used is displayed. If an invalid data rate is entered, the
default of 56 Kbps will use used. Because dial out is only provided for PPP devices, the
device type is always PPP.
One of the following messages will then be displayed:
Call initiated
This response indicates that a
call peer
request was performed. This does not always
imply that a request reached the telephone switch.
Call attempt failed
This response indicates that the request could not be executed.
Note: The
call peer <phone number>
command will not work under the following
conditions:
If PAP or CHAP is enabled and Outbound Authentication is disable, or, if the only
security enabled is CLID. In either case, the CyberSWITCH will not be able to
authenticate the remote peer. A message will appear in the log to indicate this. Use the
call device <device name>
command instead.
disc device <device name>
Disconnects all calls to the specified device. To obtain the device name, enter the Manage Mode
and issue the
device
command. Note that the device name is case sensitive.
In response to the
disc device
command, one of the following responses will be displayed:
Disconnecting <device name>
Indicates that the disconnect process has been initiated for the indicated device.
No active connection to <device name>
Indicates that the device that you are attempting to disconnect has no active connection.
The
mc
or the
cs
command can be used to view the active connections.
<device name> could not be found in the Device Table
Indicates that the device name could not be found in the table of configured device names.
More than one match for <device name> found in the Device Table
Displayed if you enter just part of a device name and that part could specify more than one
device name. You will be prompted to enter the device name again, in a more specific
manner. For example, if
call device Sch
is entered, and there is a device configured
with the name Schultz, and a device configured with the name Schmidt, this message
would be displayed. You would then need to enter at least
call device Schu
to
successfully initiate a call to the device Schultz.
Re-enter the name, or <RET> to cancel
The device name must be re-entered.
Page view 594
1 2 ... 590 591 592 593 594 595 596 597 598 599 600 ... 728 729

Comments to this Manuals

No comments