Enterasys Networks CSX7000 User Manual Page 583

  • Download
  • Add to my manuals
  • Print
  • Page
    / 729
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 582
Central Site Remote Access Switch 583
S
YSTEM
C
OMMANDS
Viewing Throughput Information
Note: If data compression is being used, an extra line will be displayed on the Connection
Monitor screen that will provide the compression and decompression ratios, and the
estimated throughput. The estimated throughput is calculated as follows:
est. thruput (in Kbits/second) = [(uncmp bits + undmp bits)/sample period)]/1000
Where uncmp bits = the number of uncompressed bits
undmp bits = the number of undecompressed bits
sample period = configured length of the sample period
THROUGHPUT MONITOR CONTENTS
#1. Indicates the site name for the connected site that was selected on the Connection Monitor
screen.
#2. Indicates the current bandwidth in place to the connected site. This number will be
updated as calls are added or released.
#3. Example of three samples where actual bandwidth utilization was around 95% and
underload was not being monitored (probably because only one connection was in place).
In this example, overload is occurring on all three samples.
100
30
0
8 16 24 32
Throughput Monitor
Wide Area Network Bandwidth Utilization to site sitename @ current bandwidth Kbps
#1
#2
= UNDERLOAD BANDWIDTH = ACTUAL BANDWIDTH UTILIZATION
Sample Rate (seconds): 03
Overload: Trigger 01 Window 02 Utilization (%) 10
Underload: Trigger 05 Window 10
Idle: Trigger 05 Window 05 Utilization (%) 10
Throughput Parameters
< Press F to Freeze data capture, Esc to return to Connection Monitor >
% of current
bandwidth
Samples
Page view 582
1 2 ... 578 579 580 581 582 583 584 585 586 587 588 ... 728 729