System Message Summary
LAN Port is now in the Listening state
The bridge LAN port is entering the specified state.
LAN Port <port #> is now in the <new state> state
The bridge LAN port indicated is entering the specified new state.
LAN Xmit Error
LAN connection failure. LAN packet transmit error detected by the system.
Layer 1 sync not seen - Slot=<slot #> Port=<port#> Ces=<communication endpoint suffix
A physical problem has been detected on the indicated line. Check for proper connection to the
CyberSWITCH and to the NT1 or CIU. If the NT1 or CIU appears functioning properly, call your
phone company and report the problem.
[LCP] Option Negotiation Failure, Non-Convergence detected
Link Control Protocol is terminated because the CyberSWITCH and the device cannot agree on a
common way of communicating. The device may not be configured properly. Refer to the specific
documentation for device set up. Then, contact your Distributor or Customer Support.
Line <slot #, port #> Down
ISDN line failure. The data link for the line connected to slot <slot #> port <port #> is down.
LMI alarm on Access <access index>
Indicates that either no STATUS messages have been received from the network or that N393 errors
have occurred in the last N391 events thus exceeding the device configured alarm threshold for the
LMI link. Any associated PVCs are disabled. (The variable N393 is the configured Monitored
Events Count, and the variable N391 is the configured Full Status Enquiry Polling Count.)
LMI alarm reset Access <access index>
Indicates that N392 events have occurred which allows the LMI alarm condition to be cleared and
any associated PVCs to be re-enabled. (The variable N392 is the configured Error Threshold Count.)
Loop detected on Local Area Network
The LAN adapter has detected a loop condition on the local area network. The system will discard
these frames until the loop condition is removed.
MAC Layer Bridge did not Initialize
A system problem prevented the MAC layer bridge from properly initializing, and the bridge will
not forward data over the WAN. Restart the system. If the error continues, contact your Distributor
or Customer Support.
Manage Mode updates have been successfully committed
The above message indicates that the Dynamic Management commit command was successfully
completed.
Manual intervention required: please replace LAN card
Older versions of the Ethernet adapter may need to be updated or replaced to run Release 2.3 or
greater. If the above message appears in your system log messages, you will need to replace your
Ethernet adapter.