System Platforms
6. Insert the clean and dry air filter back into its slot behind the chassis front. Tilt the filter forward
into place until it is flush against the chassis front panel.
7. Reinstall the two retaining screws along the top lip of the chassis.
8. Replace the system’s top cover.
9. Reconnect the power cord and power up the system.
P
LATFORM CHARACTERISTICS
Physical Characteristics
Height: 178 mm (7.0 in)
Width: 432 mm (17.0 in)
Depth: 452 mm (17.8 in)
Weight: 22 kg maximum (44 lb. maximum)
Environmental Characteristics
Operating Temp: 0° to 50° C (41° to 122° F)
Operating Humidity: 20 - 85% non-condensing
Operating Altitude: 3048 m maximum (10,000 ft maximum)
Non-operating Shock: 40 G, 11 ms 1/2 sine wave
Storage Temperature: -25° to +70° C (-13° to 158° F)
Electrical AC Power Input
Voltage: 90 - 135 V Current:5 A
Voltage: 180 - 265 V Current:4 A
Frequency: 47 - 63 Hz
Regulatory Compliance
Meets or exceeds the following:
Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 950,
and 72/23/EEC
EMI: FCC Part 15, EN 55022, CSA 108.8, EN 50082-1,
VCCI V-3, and 89/336/EEC