Enterasys-networks 1G58x-09 User Manual Page 792

  • Download
  • Add to my manuals
  • Print
  • Page
    / 808
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 791
Security Configuration Command Set
Configuring Flow Setup Throttling (FST)
14-110 Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
14.3.9.6 set flowlimit shutdown
Use this command to enable or disable the flow limit shut down function. When enabled, this allows
ports configured with a “disable” action to shut down. For information on using the set flowlimit
limit command to configure set a disable action on a port, refer to Section 14.3.9.3.
set flowlimit shutdown {enable | disable}
Syntax Description
Command Type
Switch command.
Command Mode
Read-Write.
Command Defaults
None.
Example
This example shows how to enable the flow limit shut down function:
enable | disable Enables or disables the flow limit shut down function.
Matrix>set flowlimit shutdown enable