Summary of Contents

Page 1 - FAST ETHERNET SWITCH

9033718-01VERTICAL HORIZONVH-8TX1UM/VH-8TX1MFFAST ETHERNET SWITCHUSER GUIDE

Page 2

Noticex 9033718-01

Page 3 - 9033718-01 iii

9033718 Table of Contents xiTABLE OF CONTENTSPREFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 4

xii Table of Contents VH-8TX1MFConsole Port (Out-of-Band) Connections . . . . . . . . . . . . . . . . . . . 18Remote Management via the Console Port

Page 5 - 9033718-01 v

9033718-01 Preface xiiiPREFACEPurposeThis guide provides information about the features and applications of the Enterasys Networks Vertical Horizon V

Page 6 - SAFETY INFORMATION

xiv Preface VH-8TX1UM/VH-8TX1MFOther ConventionsThis guide uses the following typographical conventions:• Initial Caps Menu titles and console menu s

Page 7 - PROGRAM LICENSE AGREEMENT

9033718-01 Product Overview 11. PRODUCT OVERVIEWThis chapter provides the following information:• Product Description• Features• Front and Rear Panel

Page 8

2 Product Overview VH-8TX1UM/VH-8TX1MFThe VH-8TX1UM/VH-8TX1MF switch is desktop mountable. LEDs on the front panel provide information about the oper

Page 9 - DECLARATION OF CONFORMITY

9033718-01 Product Overview 3Front PanelFigure 1-1 shows the front panel of the Enterasys Networks Vertical Horizon VH-8TX1UM/VH-8TX1MF. Table 1-1 de

Page 10 - 9033718-01

4 Product Overview VH-8TX1UM/VH-8TX1MFRear PanelFigure 1-2 shows the VH-8TX1UM/VH-8TX1MF rear panel and Table 1-2 defines the rear panel components.

Page 11 - TABLE OF CONTENTS

9033718-01 Product Overview 5fails for any reason, a disabled alternative is activated, thereby maintaining the connection. This prevents network tra

Page 13 - Conventions

6 Product Overview VH-8TX1UM/VH-8TX1MFAn RS-232 connection, using a DB-9 connector, is included on the rear panel for system management. Serial conso

Page 14 - Organization

9033718-01 Product Overview 7• Event: a function that operates with the Alarm group to define an action that will be taken when an alarm condition oc

Page 15 - 1. PRODUCT OVERVIEW

8 Product Overview VH-8TX1UM/VH-8TX1MFaddress that matches one in the authorized list will be forwarded, all other packets will be dropped. Note that

Page 16 - Features

9033718-01 Product Overview 9that could add to a congestion condition. The VH-8TX1UM/VH-8TX1MF switch supports flow control per the IEEE 802.3x stand

Page 17 - Front Panel

10 Product Overview VH-8TX1UM/VH-8TX1MFFactory DefaultsTable 1-3 lists the default settings for switch configuration parameters. Each parameter can b

Page 18 - Feature Summaries

9033718-01 Product Overview 11Application ExamplesThe exploding popularity of the Internet and of corporate intranets, as well as new, high-bandwidth

Page 19 - • Serial console, out-of-band

12 Product Overview VH-8TX1UM/VH-8TX1MFClient/Server Network ApplicationTo improve workstation performance in a client/server environment, the VH-8TX

Page 20

9033718-01 Product Overview 13Local Backbone ApplicationThe VH-8TX1UM/VH-8TX1MF switch can be used in a local backbone application, connecting networ

Page 21 - Port Security

14 Product Overview VH-8TX1UM/VH-8TX1MF

Page 22 - Flow Control

9033718-01 Installation 152. INSTALLATIONInspecting Your ShipmentWhen you receive the shipment of your switch, check the package contents and make su

Page 23 - Port Trunking

Notice9033718-01 iiiNOTICEEnterasys Networks reserves the right to make changes in specifications and other information contained in this document wit

Page 24 - Factory Defaults

16 Installation VH-8TX1UM/VH-8TX1MFMounting the Switch on a Table or ShelfYou can mount the switch on a table or shelf. Locate the switch in a positi

Page 25 - Application Examples

9033718-01 Installation 17Mounting the Switch in a RackThe switch ships with two (2) multi-position mounting ears and four (4) mounting screws. Figur

Page 26

18 Installation VH-8TX1UM/VH-8TX1MFConnecting a Terminal to the Console PortThe console port is a serial RS-232 interface port that enables a connect

Page 27 - Local Backbone Application

9033718-01 Installation 192. Connect one end of the interface cable directly to the switch’s console port and tighten the retaining screws.3. Connect

Page 28

20 Installation VH-8TX1UM/VH-8TX1MFPowering the SwitchTo supply power to the switch, connect the power cord to the switch and to a grounded three-pro

Page 29 - 2. INSTALLATION

9033718-01 Installation 21Network Cable RequirementsCopperTable 2.1 specifies the cable types and length constraints for the various copper interface

Page 30

22 Installation VH-8TX1UM/VH-8TX1MF10Base-T/100Base-TX PortsThe 10Base-T/100Base-TX ports use RJ-45 connectors. Figure 2-4 shows an RJ-45 connector b

Page 31 - Mounting the Switch in a Rack

9033718-01 Installation 23100Base-FX Fiber PortThe 100Base-FX fiber port uses an SC connector. Figure 2-5 shows an SC fiber connector being inserted

Page 32

24 Installation VH-8TX1UM/VH-8TX1MF

Page 33 - In-Band Connections

9033718-01 Technical Specifications 25APPENDIX A. TECHNICAL SPECIFICATIONSGeneralStandards ComplianceIEEE 802.1D Transparent Bridging Specifications

Page 34 - Powering the Switch

Noticeiv 9033718-01FCC NOTICEThis device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device

Page 35 - Network Cable Requirements

26 Technical Specifications VH-8TX1UM/VH-8TX1MFElectrical SpecificationsInput voltage: 100-240 VACInput frequency: 50-60 HzMaximum power consumption:

Page 36 - 10Base-T/100Base-TX Ports

9033718-01 Technical Specifications 27Port SpecificationsConsole PortTable A-1 shows the console port pin assignments.Table A-1. RS-232 Console Port

Page 37 - 100Base-FX Fiber Port

28 Technical Specifications VH-8TX1UM/VH-8TX1MFMDI/MDI-X Crossover Cable WiringFigure A-1 shows the wiring scheme for implementing a crossover cable

Page 38

9033718-01 Technical Specifications 29Country-Specific RequirementsTable A-3 lists the power cord set requirements by country and identifies the accr

Page 39 - Environmental Specifications

30 Technical Specifications VH-8TX1UM/VH-8TX1MFNote 2Flexible cord must be Type SV, SJ, SPT or equivalent, No. 18 AWG, 3-conductor. Wall plug must be

Page 40 - Physical Specifications

9033718 Flow Control 31APPENDIX B. FLOW CONTROLFlow control is a mechanism which allows you to protect the switch from overload conditions and to kee

Page 41 - Port Specifications

32 Flow Control VH-8TX1MF

Page 42 - Power Cord Set Requirements

9033718 Acronyms & Abbreviations 33APPENDIX C. ACRONYMS & ABBREVIATIONSTerm Definition10Base-T 10 Mbps twisted-pair Ethernet100Base-TX 100 Mb

Page 43 - Country-Specific Requirements

34 Acronyms & Abbreviations VH-8TX1MFTXD Transmit DataUTP Unshielded Twisted PairVLAN Virtual LANTerm Definition

Page 44

9033718 Index 1INDEX10Base-T/100Base-TX ports, 22802.1D, 4802.1p, 9802.1Q, 2, 9802.3, 22802.3x, 9Aapplication examples, 11architecture of switch, 2aut

Page 45 - APPENDIX B. FLOW CONTROL

Notice9033718-01 v• 21 CFR 1040.10 and 1040.11 U.S. Department of Health and Human Services (FDA). • IEC Publication 825 (International Electrotechnic

Page 46 - 32 Flow Control VH-8TX1MF

2 Index VH-8TX1MFload balancing, 9local backbone application, 13location requirements, 15Mmanagement interfaces, 5MDI, 22MDI-X, 22, 27memory tests, 2

Page 47

9033718 Index 3WWeb-based network manager, 6XXMODEM download, 5, 20

Page 48 - Term Definition

4 Index VH-8TX1MF

Page 51 - XMODEM download, 5, 20

Noticevi 9033718-01SAFETY INFORMATIONWICHTIGE SICHERHEITSHINWEISE (GERMANY)1. Bitte lesen Sie diese Hinweise sorgfältig durch.2. Heben Sie diese Anl

Page 52 - 4 Index VH-8TX1MF

Notice9033718-01 viiENTERASYS NETWORKS, INC.PROGRAM LICENSE AGREEMENTBEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,CAREFULLY READ THIS LICENSE AGRE

Page 53

Noticeviii 9033718-015. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Product (i) was developed solely at private expense; (ii) contains “r

Page 54 - 150728-102 R02

Notice9033718-01 ixDECLARATION OF CONFORMITYApplication of Council Directive(s): 89/336/EEC73/23/EECManufacturer’s Name: Enterasys Networks, Inc.Manuf